Direct answer: yes, wherever a 2012 or later IRC applies without a local amendment. IRC §R302.5.1 has required a self-closing device on the door between an attached garage and the house since the 2012 edition, and the 2021 and 2024 editions also require the door to be self-latching. See the full article, garage door hinges and how to adjust spring hinge tension.

The Code

Q: Does the door from the garage into the house have to be self-closing?
Yes, under the 2012 and later IRC. §R302.5.1 says the door must be “equipped with a self-closing device” (2012, 2015), “a self-closing or automatic-closing device” (2018), and from 2021 “Doors shall be self-latching and equipped with a self-closing or automatic-closing device.” For Waterson K51M: a self-closing hinge set replaces the butt hinges and is the self-closing device.
Q: Does the garage door also have to latch by itself?
Under the 2021 and 2024 IRC, yes. The door must be self-latching, so the closer has to carry it past the latch every time. For Waterson K51M: speed control lets the spring stay strong enough to latch; the SA1 hinge in the A3 set provides latch speed control.
Q: What kind of door is allowed between the garage and the house?
Solid wood at least 1-3/8″ thick, solid or honeycomb-core steel at least 1-3/8″ thick, or a 20-minute fire-rated door (IRC §R302.5.1). For Waterson K51M: the K51M-400 is listed for 1-3/8″ doors and the K51M-450 for 1-3/4″ doors.
Q: Does the garage-to-house door have to be fire-rated?
Not under the IRC text. A 20-minute rated door is one of three options; a solid wood door or a solid or honeycomb-core steel door of the minimum thickness also complies. For Waterson K51M: it is UL listed and permitted by NFPA 80 on fire door assemblies rated up to 3 hours, so it also suits a rated door.
Q: Can a garage door open straight into a bedroom?
No. IRC §R302.5.1 does not permit openings from a private garage directly into a room used for sleeping.
Q: My house is older. Do I have to add a closer?
The 2009 IRC did not require one, so an older door may have been legal when built. Whether an existing door must be upgraded depends on your local rules for existing buildings and replacement work; a home-sale inspection does not by itself trigger an upgrade.
Q: Do all states require it?
No. States and cities amend the IRC. South Carolina’s adopted §R302.5.1, for example, keeps the door construction rules but omits the self-closing device (S.C. Code Regs. 8-1206). Check with your building department.
Q: What about apartment buildings under the IBC?
Most townhouses fall under the IRC. For buildings under the IBC, IBC (2021) §406.3.2.1 requires the door between a private garage and a dwelling unit to be self-closing and self-latching, with the same 1-3/8″ solid door or 20-minute rated door options.

The Hardware

Q: Do self-closing hinges count as a self-closing device?
The IRC does not name a device type; it asks that the door close. Self-closing hinges, spring hinges and overhead closers are all used; your inspector decides. For Waterson K51M: the hinge fits the standard ANSI mortise pocket, a direct drop-in replacement for standard butt hinges with no additional door modification.
Q: How many hinges does a garage entry door need?
Usually three on an ordinary 36″ × 80″ door. For Waterson K51M: a 3-hinge set is rated for doors up to 7′ × 4′ and 260 lbs; at 234 lbs or more, 90 % of that rating, add a fourth hinge.
Q: How do I stop a self-closing garage door from slamming?
Use speed control instead of a weaker spring, which may stop latching. For Waterson K51M: every current model has speed control; B sets add hydraulic damping for a quieter close, A sets use mechanical friction.
Q: Should I use a hold-open hinge on a garage door?
Not on this door. A hold-open with no release keeps the door open; the code’s alternative, an automatic-closing device, closes the door when a fusible link or detector trips. For Waterson K51M: choose an A or B set; C and D sets include the SB hinge that holds the door at 85° ±5°.
Q: Will a self-closing hinge last on a door used many times a day?
Pick a tested hinge. For Waterson K51M: ANSI/BHMA A156.17 Grade 1, tested to more than 1,000,000 cycles, in investment-cast stainless steel.
Q: How should I adjust the hinges so the door passes inspection?
The code does not spell out a test. In practice: hang the door square, raise spring tension until it latches from fully open and from a few inches open, then slow the swing. For Waterson K51M: B sets are hydraulic hybrid; after any speed change, recheck that the door still latches.

Related: spring loaded garage door hinges, soft-close without self-close, residential door hinges.